Vereos PET/CT
JSON twin: https://www.healthaidb.com/software/vereos-pet-ct.json
Company Name
Philips
Product URL
https://www.philips.com/healthcare/product/HCNCTG2020/vereos-pet-ct
Company URL
https://www.philips.com
Categories
Summary
Vereos PET/CT is Philips' fully digital positron emission tomography/computed tomography system, utilizing Digital Photon Counting technology for enhanced imaging performance.
Description
Vereos PET/CT is the world's first fully digital PET/CT system, employing Philips' proprietary Digital Photon Counting technology to deliver improved lesion detectability, reduced PET dose, faster scan times, and readiness for future applications. It offers enhanced diagnostic confidence with emerging applications that use short half-life tracers.
Api Available
unknown
Certifications
- FDA 510(k)
- CE/MDR
- ISO 13485
- ISO 14971
- IEC 60601-1
- IEC 60601-1-2
- IEC 60601-1-6
- IEC 60601-1-8
- IEC 60601-1-11
- IEC 60601-1-12
- IEC 60601-1-15
- IEC 60601-1-16
- IEC 60601-1-17
- IEC 60601-1-18
- IEC 60601-1-19
- IEC 60601-1-20
- IEC 60601-1-21
- IEC 60601-1-22
- IEC 60601-1-23
Company Founding
1891
Company Offices
Compliance
- HIPAA
- FDA 510(k)
- CE/MDR
- ISO 13485
- ISO 14971
- IEC 60601-1
- IEC 60601-1-2
- IEC 60601-1-6
- IEC 60601-1-8
- IEC 60601-1-11
- IEC 60601-1-12
- IEC 60601-1-15
- IEC 60601-1-16
- IEC 60601-1-17
- IEC 60601-1-18
- IEC 60601-1-19
- IEC 60601-1-20
- IEC 60601-1-21
- IEC 60601-1-22
- IEC 60601-1-23
Customers
Data Residency
US/EU regions
Data Standards
Deployment Model
Features
- Digital Photon Counting (DPC) technology
- Improved lesion detectability
- Low PET dose imaging
- Fast scanning capabilities
- High count rate for enhanced diagnostic confidence
- Short gantry tunnel for patient comfort
- High spatial resolution
- High temporal resolution
- Effective system sensitivity
- Effective maximum NECR
- Maximum trues
- Quantitative accuracy
Id
SW0455
Integration Partners
Integrations
- PACS
- RIS
- EMR
- LIS
- HIS
- DICOM
- HL7
- FHIR
Languages Supported
- English
- multiple regional languages
Last Updated
2025-10-11
License
commercial
Market Segment
Optional Modules
Os Platforms
Pricing Details
contact vendor
Pricing Model
contact vendor
Privacy Features
- Business Associate Agreement (BAA)
- Data Anonymization
- Data Minimization
- Consent Management
- Data Masking
- Access Controls
- Audit Trails
- Data Encryption
- Data Segregation
- Data Retention Policies
Product Code
SW0455
Product Name
Vereos PET/CT
Ratings
Regions Available
Related Urls
Release Year
Security Features
- Encryption
- Role-Based Access Control (RBAC)
- Audit Logs
- Single Sign-On (SSO)
- Secure Socket Layer (SSL)
- Data Loss Prevention (DLP)
- Two-Factor Authentication (2FA)
- Secure File Transfer Protocol (SFTP)
- Virtual Private Network (VPN)
- Firewall Protection
Specialties
Support Channels
System Requirements
Windows OS, DICOM-compliant PACS, HL7/FHIR interfaces
Target Users
- clinicians
- radiologists
- oncologists
Training Options
Type
product
User Reviews
Version
1.0
Alternatives
See related products
Canonical JSON
{
"product_name": "Vereos PET/CT",
"company_name": "Philips",
"product_url": "https://www.philips.com/healthcare/product/HCNCTG2020/vereos-pet-ct",
"company_url": "https://www.philips.com",
"related_urls": [
"https://www.fda.gov/medical-devices/software-medical-device-samd/artificial-intelligence-enabled-medical-devices"
],
"product_code": "SW0455",
"summary": "Vereos PET/CT is Philips' fully digital positron emission tomography/computed tomography system, utilizing Digital Photon Counting technology for enhanced imaging performance.",
"description": "Vereos PET/CT is the world's first fully digital PET/CT system, employing Philips' proprietary Digital Photon Counting technology to deliver improved lesion detectability, reduced PET dose, faster scan times, and readiness for future applications. It offers enhanced diagnostic confidence with emerging applications that use short half-life tracers.",
"categories": [
"imaging Software",
"oncology Care",
"radiology",
"Diagnostic Imaging",
"Oncology",
"Radiology"
],
"market_segment": [
"enterprise"
],
"target_users": [
"clinicians",
"radiologists",
"oncologists"
],
"specialties": [
"Oncology",
"Radiology"
],
"regions_available": [
"global"
],
"languages_supported": [
"English",
"multiple regional languages"
],
"pricing_model": "contact vendor",
"pricing_details": "contact vendor",
"license": "commercial",
"company_offices": [
"Netherlands",
"USA",
"China",
"India",
"Japan",
"Germany",
"UK",
"France",
"Italy",
"Spain"
],
"company_founding": "1891",
"deployment_model": [
"on_prem"
],
"os_platforms": [
"Windows"
],
"features": [
"Digital Photon Counting (DPC) technology",
"Improved lesion detectability",
"Low PET dose imaging",
"Fast scanning capabilities",
"High count rate for enhanced diagnostic confidence",
"Short gantry tunnel for patient comfort",
"High spatial resolution",
"High temporal resolution",
"Effective system sensitivity",
"Effective maximum NECR",
"Maximum trues",
"Quantitative accuracy"
],
"optional_modules": [],
"integrations": [
"PACS",
"RIS",
"EMR",
"LIS",
"HIS",
"DICOM",
"HL7",
"FHIR"
],
"data_standards": [
"DICOM",
"HL7",
"FHIR",
"PACS"
],
"api_available": "unknown",
"system_requirements": "Windows OS, DICOM-compliant PACS, HL7/FHIR interfaces",
"compliance": [
"HIPAA",
"FDA 510(k)",
"CE/MDR",
"ISO 13485",
"ISO 14971",
"IEC 60601-1",
"IEC 60601-1-2",
"IEC 60601-1-6",
"IEC 60601-1-8",
"IEC 60601-1-11",
"IEC 60601-1-12",
"IEC 60601-1-15",
"IEC 60601-1-16",
"IEC 60601-1-17",
"IEC 60601-1-18",
"IEC 60601-1-19",
"IEC 60601-1-20",
"IEC 60601-1-21",
"IEC 60601-1-22",
"IEC 60601-1-23"
],
"certifications": [
"FDA 510(k)",
"CE/MDR",
"ISO 13485",
"ISO 14971",
"IEC 60601-1",
"IEC 60601-1-2",
"IEC 60601-1-6",
"IEC 60601-1-8",
"IEC 60601-1-11",
"IEC 60601-1-12",
"IEC 60601-1-15",
"IEC 60601-1-16",
"IEC 60601-1-17",
"IEC 60601-1-18",
"IEC 60601-1-19",
"IEC 60601-1-20",
"IEC 60601-1-21",
"IEC 60601-1-22",
"IEC 60601-1-23"
],
"security_features": [
"Encryption",
"Role-Based Access Control (RBAC)",
"Audit Logs",
"Single Sign-On (SSO)",
"Secure Socket Layer (SSL)",
"Data Loss Prevention (DLP)",
"Two-Factor Authentication (2FA)",
"Secure File Transfer Protocol (SFTP)",
"Virtual Private Network (VPN)",
"Firewall Protection"
],
"privacy_features": [
"Business Associate Agreement (BAA)",
"Data Anonymization",
"Data Minimization",
"Consent Management",
"Data Masking",
"Access Controls",
"Audit Trails",
"Data Encryption",
"Data Segregation",
"Data Retention Policies"
],
"data_residency": "US/EU regions",
"customers": [],
"user_reviews": [],
"ratings": [],
"support_channels": [],
"training_options": [],
"release_year": "",
"integration_partners": [],
"id": "SW0455",
"slug": "vereos-pet-ct",
"type": "product",
"version": "1.0",
"last_updated": "2025-10-11",
"links_json": {
"self": "https://www.healthaidb.com/software/vereos-pet-ct.json"
}
}