JSON twin: https://www.healthaidb.com/software/lungqtm-clinical-suite.json
Thirona
AI-powered CT lung image analysis platform that automatically segments and quantifies airways, vasculature and parenchyma to support clinical care and research.
LungQ™ Clinical Suite (Thirona) is a validated AI-based lung quantification platform that performs automated multi-level segmentation and quantitative measurements from chest CT (airways, pulmonary vasculature, lobar/segmental parenchyma). It provides reproducible metrics for emphysema, air trapping, airway disease, vascular abnormalities and other lung pathologies, and is positioned for clinical use, interventional planning and clinical research/clinical trials. Regulatory availability and specific analyses vary by geography and version (FDA 510(k) cleared for recent versions).
yes
2014
EU hosting available; US hosting/availability via integration partners (regional hosting options via partners)
P2070
2025-09-07
proprietary commercial
Contact vendor for licensing, deployment and pricing (no public list prices; enterprise / site-license arrangements; demo/trial on request).
enterprise_quote
2016
DICOM connectivity/PACS integration; web browser client; server deployment Linux/Windows for on‑prem; GPU recommended for inference (if on‑prem)
product
1.0
{ "company_name": "Thirona", "company_url": "https://thirona.eu", "company_offices": [ "Netherlands" ], "company_founding": "2014", "product_url": "https://thirona.eu/lungq/", "categories": [ "clinical", "diagnostic", "medical imaging", "AI/ML", "pulmonary", "research" ], "market_segment": [ "enterprise" ], "links": [ "https://thirona.eu/lungq/", "https://thirona.eu/about-us/", "https://thirona.eu/press-release/lungq-3-0-0-receives-fda-510k-clearance/", "https://accessdata.fda.gov/cdrh_docs/pdf23/K232412.pdf", "https://radiology.healthairegister.com/products/thirona-lungq", "https://incepto-medical.com/product/lungq", "https://thirona.eu/publications/", "https://thirona.eu/contactus/" ], "summary": "AI-powered CT lung image analysis platform that automatically segments and quantifies airways, vasculature and parenchyma to support clinical care and research.", "description": "LungQ™ Clinical Suite (Thirona) is a validated AI-based lung quantification platform that performs automated multi-level segmentation and quantitative measurements from chest CT (airways, pulmonary vasculature, lobar/segmental parenchyma). It provides reproducible metrics for emphysema, air trapping, airway disease, vascular abnormalities and other lung pathologies, and is positioned for clinical use, interventional planning and clinical research/clinical trials. Regulatory availability and specific analyses vary by geography and version (FDA 510(k) cleared for recent versions).", "target_users": [ "radiologists", "pulmonologists", "interventional pulmonologists", "thoracic surgeons", "clinical researchers", "clinical trial teams", "hospital IT/diagnostic imaging departments", "medical physicists" ], "specialties": [ "pulmonology", "thoracic radiology", "interventional pulmonology", "respiratory medicine", "cardiopulmonary imaging", "clinical research / trials" ], "regions_available": [ "Europe", "United Kingdom", "United States", "Australia" ], "languages_supported": [ "English" ], "pricing_model": "enterprise_quote", "pricing_details": "Contact vendor for licensing, deployment and pricing (no public list prices; enterprise / site-license arrangements; demo/trial on request).", "license": "proprietary commercial", "deployment_model": [ "SaaS", "on_prem", "cloud" ], "os_platforms": [ "Web" ], "features": [ "Automated lung, lobe and airway segmentation", "Quantitative lobar and whole‑lung volume measurements", "Emphysema quantification and lobar severity metrics", "Interlobar fissure completeness assessment", "Bronchial anatomy analysis (Bronchi-suite)", "Pulmonary vascular quantifications (Vascular-suite)", "Longitudinal CT comparison and progression monitoring", "Automatic CT normalization for reproducible results", "Visual overlays and annotated image reports", "Report generation for clinical decision support", "Treatment planning support for interventional pulmonology", "DICOM import/export and integration with imaging workflows", "Quality control / reproducibility checks" ], "optional_modules": [ "COPD/emphysema module", "Fissure completeness analysis", "Bronchi (bronchial) analysis module", "Vascular analysis module", "Longitudinal follow‑up / comparison module" ], "integrations": [ "Philips HealthSuite", "Incepto (partner platform)", "Blackford (partner platform)", "PACS", "RIS", "Hospital EHR systems (via integration partners)", "DICOM viewers", "Clinical workflow/orchestration platforms" ], "data_standards": [ "DICOM", "HL7 v2", "FHIR", "SNOMED CT", "ICD‑10" ], "api_available": "yes", "system_requirements": "DICOM connectivity/PACS integration; web browser client; server deployment Linux/Windows for on‑prem; GPU recommended for inference (if on‑prem)", "compliance": [ "CE (Class IIb, DEKRA)", "FDA 510(k) clearance (K232412)", "GDPR", "HIPAA (for US deployments via partners)" ], "certifications": [ "CE Mark (Class IIb, Notified Body: DEKRA 0344)", "FDA 510(k) K232412" ], "security_features": [ "Encryption in transit", "Encryption at rest", "Role‑based access control (RBAC)", "SSO/SAML integration", "Audit logging", "Two‑factor authentication (where supported)" ], "privacy_features": [ "Consent management", "Anonymization/pseudonymization of imaging data", "Data minimization" ], "data_residency": "EU hosting available; US hosting/availability via integration partners (regional hosting options via partners)", "customers": [], "user_reviews": [], "ratings": [], "support_channels": [ "email" ], "training_options": [], "release_year": "2016", "integration_partners": [ "Blackford Analysis", "Incepto", "StratX" ], "id": "P2070", "slug": "lungqtm-clinical-suite", "type": "product", "version": "1.0", "last_updated": "2025-09-07", "links_json": { "self": "https://www.healthaidb.com/software/lungqtm-clinical-suite.json" } }