JSON twin: https://www.healthaidb.com/software/e-cta.json
Brainomix
https://www.brainomix.com/stroke/e-cta/
e-CTA by Brainomix is an AI-driven decision-support software that automatically detects large vessel occlusions (LVO) and standardizes collateral assessment on CT angiography to support acute stroke workflow.
e-CTA analyses single- and multi-phase CT angiography to detect and localize LVOs, estimate arterial/venous phases, compute a CTA collateral score (CTA-CS) with color heat-map visualization, and generate standardized visual reports to support clinician decision-making in acute stroke care. It is CE marked and FDA cleared as part of the Brainomix stroke imaging suite.
yes
2010
Support for on-prem deployment or cloud hosting with US and EU region options
P1947
2025-09-07
commercial proprietary
Contact vendor for licensing, deployment and pricing; trial/demo availability by request
enterprise_quote
2019
DICOM-capable PACS/VNA connectivity; server (Windows/Linux) deployment option; GPU recommended (NVIDIA) for accelerated processing; secure network/TLS
product
1.0
{ "company_name": "Brainomix", "company_url": "https://www.brainomix.com", "company_offices": [ "United Kingdom", "Ireland", "United States" ], "company_founding": "2010", "product_url": "https://www.brainomix.com/stroke/e-cta/", "categories": [ "clinical", "diagnostic", "medical imaging", "decision support", "stroke", "AI/machine learning" ], "market_segment": [ "enterprise", "hospital", "health system" ], "links": [ "https://www.brainomix.com/stroke/e-cta/", "https://www.brainomix.com/", "https://www.brainomix.com/media/i3bjuu2y/e-cta_advanced-solutions-to-support-stroke-treatment-decisions_hd.pdf", "https://healthairegister.com/products/brainomix-e-cta", "https://www.rcr.ac.uk/our-services/artificial-intelligence-ai/ai-registry/e-cta/", "https://pmc.ncbi.nlm.nih.gov/articles/PMC8739618/", "https://pubmed.ncbi.nlm.nih.gov/39878893/", "https://vimeo.com/576763433", "https://www.accessdata.fda.gov/cdrh_docs/pdf19/K192692.pdf" ], "summary": "e-CTA by Brainomix is an AI-driven decision-support software that automatically detects large vessel occlusions (LVO) and standardizes collateral assessment on CT angiography to support acute stroke workflow.", "description": "e-CTA analyses single- and multi-phase CT angiography to detect and localize LVOs, estimate arterial/venous phases, compute a CTA collateral score (CTA-CS) with color heat-map visualization, and generate standardized visual reports to support clinician decision-making in acute stroke care. It is CE marked and FDA cleared as part of the Brainomix stroke imaging suite.", "target_users": [ "radiologists", "neuroradiologists", "stroke neurologists", "emergency physicians", "neurointerventionalists", "radiographers/technologists", "hospital administrators" ], "specialties": [ "neurology", "neuroradiology", "stroke" ], "regions_available": [ "United Kingdom", "European Union", "United States" ], "languages_supported": [ "English" ], "pricing_model": "enterprise_quote", "pricing_details": "Contact vendor for licensing, deployment and pricing; trial/demo availability by request", "license": "commercial proprietary", "deployment_model": [ "on_prem", "cloud", "hybrid" ], "os_platforms": [ "Web", "iOS", "Android", "Windows", "Linux" ], "features": [ "Automated LVO (large vessel occlusion) detection from CTA", "Automated CTA-CS collateral scoring (collateral assessment)", "Single- and multi-phase CTA support with phase estimation (AIF/VOF)", "Automatic MIP generation and multi-planar reconstructions (MPR)", "Vessel visualization and annotated heat‑maps showing asymmetry", "Visual report with affected side, LVO location and acquisition phase", "PACS integration (new series in study) and DICOM ingestion", "Email notifications with pseudonymized result images", "Mobile apps with push notifications for iOS/Android", "Interventional planning support (vessel views, peak enhancement markers)", "Processing QC / acquisition phase quality indicators", "Batch and near‑real‑time CTA processing", "Reduction of inter‑rater variability / decision support", "Exportable result images and overlays for review" ], "optional_modules": [ "e-ASPECTS (NCCT ischemia scoring)", "e-CTP (CT perfusion analysis)", "e-MRI (advanced MRI assessments)", "Triage Stroke (real-time alerting)", "Triage LVO (real-time LVO notifications)", "Core Volume / advanced volumetrics" ], "integrations": [ "PACS / VNA (DICOM)", "Email notification systems", "Mobile push services (iOS/Android)", "GE Healthcare (partner/integration references)", "Blackford (partner/integration references)", "Calantic (app gallery / distribution partner)", "Hospital IT systems / RIS", "Vendor neutral archive (VNA)" ], "data_standards": [ "DICOM", "HL7 v2", "FHIR", "SNOMED CT", "ICD-10" ], "api_available": "yes", "system_requirements": "DICOM-capable PACS/VNA connectivity; server (Windows/Linux) deployment option; GPU recommended (NVIDIA) for accelerated processing; secure network/TLS", "compliance": [ "FDA-cleared (where applicable)", "CE marked (MDR/IVDR as applicable)", "GDPR", "HIPAA" ], "certifications": [ "FDA 510(k) clearance (Brainomix e-CTA/e‑ASPECTS family)", "CE mark" ], "security_features": [ "TLS encryption in transit", "Encryption at rest", "Role-based access control (RBAC)", "SSO/SAML support", "Audit logging", "User authentication / 2FA support" ], "privacy_features": [ "BAA available for US customers", "Pseudonymization of emailed results", "Consent/privacy statements (GDPR)", "Data minimization options" ], "data_residency": "Support for on-prem deployment or cloud hosting with US and EU region options", "customers": [ "University Hospitals Sussex NHS Foundation Trust", "Dartford and Gravesham NHS Trust", "University Hospital Milton Keynes", "Cheshire and Merseyside NHS (multiple trusts)", "NHS (various trusts across UK)", "Several UK stroke centres (academic and non‑specialist hospitals)" ], "user_reviews": [], "ratings": [ "Accuracy (independent study, Wiley/ACN3): processed 82% of CTAs; sensitivity/specificity for arterial abnormality reported in range ~72–76% (study results)", "Real‑world evaluation (Stroke and Vascular Neurology): reported diagnostic performance and clinical utility in multi‑centre deployments", "CE‑marked and has FDA/510(k) references noted in literature (regulatory clearance status reported in vendor and peer‑review sources)" ], "support_channels": [ "email", "phone", "support portal/documentation" ], "training_options": [ "documentation", "webinars", "live_online", "user manuals", "demo" ], "release_year": "2019", "integration_partners": [ "Visionable (strategic partnership)", "Calantic (app gallery listing/integration partner)", "PACS and local hospital IT integrations (unnamed regional PACS vendors)", "NHS Trust implementation teams" ], "id": "P1947", "slug": "e-cta", "type": "product", "version": "1.0", "last_updated": "2025-09-07", "links_json": { "self": "https://www.healthaidb.com/software/e-cta.json" } }