JSON twin: https://www.healthaidb.com/software/briefcase-aortic-dissection-triage.json
Aidoc
https://www.aidoc.com/solutions/cardiovascular/aortic-solutions/
BriefCase - Aortic Dissection Triage is an Aidoc CT-based triage and notification software that detects suspected aortic dissection on contrast chest CT/CTA and prioritises worklists for clinicians.
Radiological computer-aided triage and notification software for analysis of chest CT/CTA in adults (18+) that flags suspected aortic dissection, provides annotated DICOM secondary captures, alert notifications, worklist prioritisation and integrations with PACS/RIS via API/HL7. Available cloud, hybrid or on-premises; CE (MDR Class IIa) and FDA 510(k) cleared (Class II).
yes
2016
On‑prem deployment option; cloud processing with regional (US/EU) hosting options
P1969
2025-09-07
commercial proprietary
Subscription model; pricing based on number of analyses. Contact vendor for commercial pricing and trial information.
subscription
—
2018
Windows Server for on‑prem components; Aidoc Cloud for processing; DICOM network connectivity
product
1.0
{ "company_name": "Aidoc", "company_url": "https://www.aidoc.com", "company_offices": [ "Israel", "United States", "Spain" ], "company_founding": "2016", "product_url": "https://www.aidoc.com/solutions/cardiovascular/aortic-solutions/", "categories": [ "clinical", "diagnostic", "radiology", "vascular", "triage", "care coordination", "patient management", "AI platform" ], "market_segment": [ "enterprise", "health system" ], "links": [ "https://www.aidoc.com/solutions/cardiovascular/aortic-solutions/", "https://www.aidoc.com/about/", "https://www.aidoc.com/about/contact/", "https://www.accessdata.fda.gov/cdrh_docs/pdf25/K251406.pdf", "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K251406", "https://healthairegister.com/companies/aidoc", "https://aicentral.acrdsi.org/Platforms/Aidoc-aiOS", "https://xrayinterpreter.com/fda?code=QAS&company=aidoc-medical&pathway=510k&tag=Task.triage", "https://www.aidoc.com/learn/product-information/take-aortic-care-to-the-next-level/", "https://www.aidoc.com/about/security-privacy/" ], "summary": "BriefCase - Aortic Dissection Triage is an Aidoc CT-based triage and notification software that detects suspected aortic dissection on contrast chest CT/CTA and prioritises worklists for clinicians.", "description": "Radiological computer-aided triage and notification software for analysis of chest CT/CTA in adults (18+) that flags suspected aortic dissection, provides annotated DICOM secondary captures, alert notifications, worklist prioritisation and integrations with PACS/RIS via API/HL7. Available cloud, hybrid or on-premises; CE (MDR Class IIa) and FDA 510(k) cleared (Class II).", "target_users": [ "radiologists", "emergency physicians", "cardiothoracic surgeons", "clinicians", "PACS administrators", "hospital IT/administrators" ], "specialties": [ "Chest", "Abdomen", "Cardiothoracic" ], "regions_available": [ "" ], "languages_supported": [ "" ], "pricing_model": "subscription", "pricing_details": "Subscription model; pricing based on number of analyses. Contact vendor for commercial pricing and trial information.", "license": "commercial proprietary", "deployment_model": [ "hybrid (on-prem + cloud)" ], "os_platforms": [ "Windows (server, desktop)", "Web" ], "features": [ "Automated analysis of contrast CT (CTA and CT with contrast) chest studies", "AI detection of suspected aortic dissection", "Case prioritization and triage notifications", "Compressed preview images for notifications (non-destructive)", "DICOM receive and processing", "De-identification of images prior to cloud processing", "Configurable operating points (sensitivity/specificity tradeoffs)", "Time-to-notification metrics and rapid alerting", "Aidoc Hospital Server for on‑prem image acquisition", "Aidoc Cloud Server for image processing", "Aidoc Desktop application for workflow integration", "Audit/performance reporting" ], "optional_modules": [ "Other BriefCase triage modules (e.g., pneumothorax, pulmonary embolism)", "Enterprise workflow integrations (advanced routing/notifications)" ], "integrations": [ "PACS (DICOM)", "VNA/DICOM archive", "Radiology workflow clients / desktop viewers (Aidoc Desktop)", "Hospital information systems / EMR (via standard interfaces)" ], "data_standards": [ "DICOM", "HL7 v2", "FHIR" ], "api_available": "yes", "system_requirements": "Windows Server for on‑prem components; Aidoc Cloud for processing; DICOM network connectivity", "compliance": [ "HIPAA" ], "certifications": [ "FDA 510(k) (K222329)" ], "security_features": [ "Encryption (in transit & at rest)", "Role-based access control (RBAC)", "Audit logging", "SSO/SAML support" ], "privacy_features": [ "De-identification prior to cloud processing", "BAA available" ], "data_residency": "On‑prem deployment option; cloud processing with regional (US/EU) hosting options", "customers": [ "Mount Sinai Health System", "Cedars-Sinai Medical Center", "Ochsner Health" ], "user_reviews": [], "ratings": [ "FDA 510(k) clearances for BriefCase family (multiple K-numbers) - source: U.S. FDA (accessdata.fda.gov)" ], "support_channels": [], "training_options": [ "documentation", "webinars", "live_online" ], "release_year": "2018", "integration_partners": [ "Amazon Web Services (AWS)", "Imbio" ], "id": "P1969", "slug": "briefcase-aortic-dissection-triage", "type": "product", "version": "1.0", "last_updated": "2025-09-07", "links_json": { "self": "https://www.healthaidb.com/software/briefcase-aortic-dissection-triage.json" } }