BriefCase
JSON twin: https://www.healthaidb.com/software/briefcase.json
Company Name
Aidoc
Product URL
https://www.aidoc.com/briefcase
Company URL
https://www.aidoc.com
Categories
Summary
BriefCase is an AI-powered software by Aidoc that assists radiologists in detecting and prioritizing urgent cases from CT scans across various body regions, enhancing workflow efficiency without altering original images.
Description
BriefCase is a radiological computer-aided triage and notification software developed by Aidoc Medical, Ltd. It analyzes CT images from multiple body regions—including head, chest, abdomen, and cervical spine—to identify critical findings such as fractures, intracranial hemorrhage, pulmonary embolism, intra-abdominal free gas, and large vessel occlusion. The software operates in parallel with standard clinical workflows, flagging suspected cases and providing notifications with low-quality preview images to expedite clinical decision-making. Importantly, BriefCase does not modify original medical images, serving solely as a triage and notification aid without replacing diagnostic processes.
Api Available
yes
Certifications
- FDA 510(k) cleared
- CE Certified, Class IIa, MDR
- ISO 13485
- ISO 14971
- IEC 62304
- IEC 62366
- IEC 60601-1
- IEC 60601-1-2
- IEC 60601-1-6
- IEC 60601-1-8
- IEC 60601-1-11
- IEC 60601-1-12
- IEC 60601-1-15
- IEC 60601-1-16
- IEC 60601-1-17
- IEC 60601-1-18
- IEC 60601-1-19
- IEC 60601-1-20
- IEC 60601-1-21
- IEC 60601-1-22
- IEC 60601-1-23
Company Founding
2016
Company Offices
Compliance
- HIPAA
- GDPR
- HITECH
- SOC 2
- ISO 27001
- ISO 13485
- FDA 21 CFR Part 820
- FDA 21 CFR Part 11
- MDR 2017/745
- ISO 14971
- IEC 62304
- IEC 62366
- IEC 60601-1
- IEC 60601-1-2
- IEC 60601-1-6
- IEC 60601-1-8
- IEC 60601-1-11
- IEC 60601-1-12
- IEC 60601-1-15
- IEC 60601-1-16
Customers
Data Residency
US/EU regions
Data Standards
- DICOM
- HL7
- FHIR
- SNOMED
- ICD-10
- LOINC
- CPT
- ICD-9
- DICOM Structured Report
- DICOM Secondary Capture
Deployment Model
Features
- Intracranial haemorrhage triage
- Aortic dissection triage
- Brain aneurysm triage
- Abdominal aortic aneurysm measurement
- Vertebral compression fracture triage
- Pneumothorax triage
- Prioritisation
- Notification
- Worklist prioritisation
- Image review software
- Desktop application
- Alert notifications
- Integration with PACS
- Integration with RIS
- Cloud-based deployment
- Locally on dedicated hardware
- Automatic analysis trigger
- Processing time: 1 - 10 minutes
Id
SW0387
Integration Partners
Integrations
- PACS
- RIS
- EHR systems
- Change Healthcare
- Merge Merative
- HL7
- API
- Bespoke integration
Languages Supported
- English
- Spanish
- French
- German
- Italian
- Portuguese
- Dutch
- Hebrew
- Japanese
- Korean
Last Updated
2025-10-11
License
commercial proprietary
Market Segment
Optional Modules
- Quantification module
- Advanced analytics module
- Reporting module
- Data visualization module
- Clinical decision support module
- Patient management module
- Workflow optimization module
- Integration with EHR systems
- Mobile application module
- Telemedicine integration module
Os Platforms
- Web
- iOS
- Android
- Windows
- macOS
- Linux
Pricing Details
Pricing based on number of analyses; contact vendor for commercial pricing and trial information.
Pricing Model
subscription
Privacy Features
- BAA available
- Consent management
- Anonymization
- Data minimization
- Data masking
- Access controls
- Data retention policies
- Data destruction policies
- Data breach notification procedures
- Data subject rights management
Product Code
SW0387
Product Name
BriefCase
Ratings
Regions Available
Related Urls
Release Year
Security Features
- Encryption
- RBAC
- SSO/SAML
- Audit logs
- 2FA
- DLP
- Firewall
- IDS/IPS
- VPN
- Endpoint security
Specialties
Support Channels
System Requirements
Windows Server 2016 or later, 16 GB RAM, 500 GB HDD, 1 Gbps network connection
Target Users
- radiologists
- emergency physicians
- clinicians
- PACS administrators
- hospital IT/administrators
Training Options
Type
product
User Reviews
Version
1.0
Alternatives
See related products
Canonical JSON
{
"product_name": "BriefCase",
"company_name": "Aidoc",
"product_url": "https://www.aidoc.com/briefcase",
"company_url": "https://www.aidoc.com",
"related_urls": [
"https://www.fda.gov/medical-devices/software-medical-device-samd/artificial-intelligence-enabled-medical-devices"
],
"product_code": "SW0387",
"summary": "BriefCase is an AI-powered software by Aidoc that assists radiologists in detecting and prioritizing urgent cases from CT scans across various body regions, enhancing workflow efficiency without altering original images.",
"description": "BriefCase is a radiological computer-aided triage and notification software developed by Aidoc Medical, Ltd. It analyzes CT images from multiple body regions—including head, chest, abdomen, and cervical spine—to identify critical findings such as fractures, intracranial hemorrhage, pulmonary embolism, intra-abdominal free gas, and large vessel occlusion. The software operates in parallel with standard clinical workflows, flagging suspected cases and providing notifications with low-quality preview images to expedite clinical decision-making. Importantly, BriefCase does not modify original medical images, serving solely as a triage and notification aid without replacing diagnostic processes.",
"categories": [
"clinical Care",
"diagnostic Support",
"radiology",
"clinical Decision Support",
"ai Clinical Documentation Integrity",
"Clinical",
"Diagnostic",
"Radiology",
"Triage",
"Ai Platform"
],
"market_segment": [
"enterprise",
"health system"
],
"target_users": [
"radiologists",
"emergency physicians",
"clinicians",
"PACS administrators",
"hospital IT/administrators"
],
"specialties": [
"Radiology",
"Emergency Medicine",
"Neurology",
"Cardiology",
"Pulmonology",
"Gastroenterology",
"Orthopedics",
"Vascular Surgery"
],
"regions_available": [
"United States",
"European Union",
"Israel",
"United Kingdom",
"Canada",
"Australia",
"Japan",
"South Korea",
"Brazil",
"India"
],
"languages_supported": [
"English",
"Spanish",
"French",
"German",
"Italian",
"Portuguese",
"Dutch",
"Hebrew",
"Japanese",
"Korean"
],
"pricing_model": "subscription",
"pricing_details": "Pricing based on number of analyses; contact vendor for commercial pricing and trial information.",
"license": "commercial proprietary",
"company_offices": [
"Israel",
"United States",
"United Kingdom"
],
"company_founding": "2016",
"deployment_model": [
"SaaS",
"on_prem",
"hybrid"
],
"os_platforms": [
"Web",
"iOS",
"Android",
"Windows",
"macOS",
"Linux"
],
"features": [
"Intracranial haemorrhage triage",
"Aortic dissection triage",
"Brain aneurysm triage",
"Abdominal aortic aneurysm measurement",
"Vertebral compression fracture triage",
"Pneumothorax triage",
"Prioritisation",
"Notification",
"Worklist prioritisation",
"Image review software",
"Desktop application",
"Alert notifications",
"Integration with PACS",
"Integration with RIS",
"Cloud-based deployment",
"Locally on dedicated hardware",
"Automatic analysis trigger",
"Processing time: 1 - 10 minutes"
],
"optional_modules": [
"Quantification module",
"Advanced analytics module",
"Reporting module",
"Data visualization module",
"Clinical decision support module",
"Patient management module",
"Workflow optimization module",
"Integration with EHR systems",
"Mobile application module",
"Telemedicine integration module"
],
"integrations": [
"PACS",
"RIS",
"EHR systems",
"Change Healthcare",
"Merge Merative",
"HL7",
"API",
"Bespoke integration"
],
"data_standards": [
"DICOM",
"HL7",
"FHIR",
"SNOMED",
"ICD-10",
"LOINC",
"CPT",
"ICD-9",
"DICOM Structured Report",
"DICOM Secondary Capture"
],
"api_available": "yes",
"system_requirements": "Windows Server 2016 or later, 16 GB RAM, 500 GB HDD, 1 Gbps network connection",
"compliance": [
"HIPAA",
"GDPR",
"HITECH",
"SOC 2",
"ISO 27001",
"ISO 13485",
"FDA 21 CFR Part 820",
"FDA 21 CFR Part 11",
"MDR 2017/745",
"ISO 14971",
"IEC 62304",
"IEC 62366",
"IEC 60601-1",
"IEC 60601-1-2",
"IEC 60601-1-6",
"IEC 60601-1-8",
"IEC 60601-1-11",
"IEC 60601-1-12",
"IEC 60601-1-15",
"IEC 60601-1-16"
],
"certifications": [
"FDA 510(k) cleared",
"CE Certified, Class IIa, MDR",
"ISO 13485",
"ISO 14971",
"IEC 62304",
"IEC 62366",
"IEC 60601-1",
"IEC 60601-1-2",
"IEC 60601-1-6",
"IEC 60601-1-8",
"IEC 60601-1-11",
"IEC 60601-1-12",
"IEC 60601-1-15",
"IEC 60601-1-16",
"IEC 60601-1-17",
"IEC 60601-1-18",
"IEC 60601-1-19",
"IEC 60601-1-20",
"IEC 60601-1-21",
"IEC 60601-1-22",
"IEC 60601-1-23"
],
"security_features": [
"Encryption",
"RBAC",
"SSO/SAML",
"Audit logs",
"2FA",
"DLP",
"Firewall",
"IDS/IPS",
"VPN",
"Endpoint security"
],
"privacy_features": [
"BAA available",
"Consent management",
"Anonymization",
"Data minimization",
"Data masking",
"Access controls",
"Data retention policies",
"Data destruction policies",
"Data breach notification procedures",
"Data subject rights management"
],
"data_residency": "US/EU regions",
"customers": [],
"user_reviews": [],
"ratings": [],
"support_channels": [],
"training_options": [],
"release_year": "",
"integration_partners": [],
"id": "SW0387",
"slug": "briefcase",
"type": "product",
"version": "1.0",
"last_updated": "2025-10-11",
"links_json": {
"self": "https://www.healthaidb.com/software/briefcase.json"
}
}