JSON twin: https://www.healthaidb.com/software/aview-copd.json
Coreline Soft
https://www.corelinesoft.com/en/solutions/copd
https://www.corelinesoft.com/en/
AVIEW COPD is an AI-assisted CT analysis software that provides automated quantitative assessment of COPD-related imaging features (emphysema, air trapping, airway and vessel measurements) from non-contrast thoracic CT scans.
AVIEW COPD (Coreline Soft) performs fully automated lung and lobe segmentation, low attenuation (LAA) analysis, emphysema quantification, fissure integrity assessment, air trapping measurement (inspiration/expiration registration), airway and pulmonary vessel analysis and generates PDF/DICOM structured reports and 3D visualisations. It can deploy on-premise, virtualized, hybrid or cloud, integrates with PACS/RIS/CIS and supports automatic or on-demand processing of standard thoracic DICOM CT datasets.
unknown
2012
On-prem deployments; cloud/hosting region options vary by customer and contract
P2020
2025-09-07
commercial proprietary
Vendor lists one-off and subscription options; pricing based on number of installations and users — contact vendor for quotes and trial information.
subscription
—
2018
DICOM-compatible CT input; Windows workstation/server; GPU recommended for AI; PACS connectivity and storage for DICOM
product
1.0
{ "company_name": "Coreline Soft", "company_url": "https://www.corelinesoft.com/en/", "company_offices": [ "South Korea", "Germany", "United States" ], "company_founding": "2012", "product_url": "https://www.corelinesoft.com/en/solutions/copd", "categories": [ "diagnostic", "clinical", "imaging", "radiology", "research" ], "market_segment": [ "enterprise", "healthcare providers", "research" ], "links": [ "https://www.corelinesoft.com/en/solutions/copd", "https://www.corelinesoft.com/en/", "https://www.corelinesoft.com/en/public/brochure/coreline_COPD_Brochure_US_FDA_web_v1.pdf", "https://healthairegister.com/radiology/products/coreline-soft-aview-copd", "https://pmc.ncbi.nlm.nih.gov/articles/PMC8484152/", "https://www.koreabiomed.com/news/articleView.html?idxno=25776", "https://www.accessdata.fda.gov/cdrh_docs/pdf19/K193220.pdf", "https://www.corelinesoft.com/en/privacy-policy" ], "summary": "AVIEW COPD is an AI-assisted CT analysis software that provides automated quantitative assessment of COPD-related imaging features (emphysema, air trapping, airway and vessel measurements) from non-contrast thoracic CT scans.", "description": "AVIEW COPD (Coreline Soft) performs fully automated lung and lobe segmentation, low attenuation (LAA) analysis, emphysema quantification, fissure integrity assessment, air trapping measurement (inspiration/expiration registration), airway and pulmonary vessel analysis and generates PDF/DICOM structured reports and 3D visualisations. It can deploy on-premise, virtualized, hybrid or cloud, integrates with PACS/RIS/CIS and supports automatic or on-demand processing of standard thoracic DICOM CT datasets.", "target_users": [ "radiologists", "pulmonologists", "thoracic clinicians", "radiology technicians", "IT/healthcare administrators" ], "specialties": [ "chest radiology", "pulmonology", "thoracic imaging" ], "regions_available": [], "languages_supported": [], "pricing_model": "subscription", "pricing_details": "Vendor lists one-off and subscription options; pricing based on number of installations and users — contact vendor for quotes and trial information.", "license": "commercial proprietary", "deployment_model": [ "on_prem", "cloud" ], "os_platforms": [ "Windows", "Web" ], "features": [ "Automated lung, lung-lobe and airway segmentation", "Emphysema quantification (LAA) and emphysema cluster analysis", "Airway analysis (airway wall thickness, luminal measures)", "Pulmonary vasculature analysis", "Phenotypic classification of COPD (airway vs emphysema types)", "3D emphysema visualization and distribution maps", "Fissure completeness analysis (optional)", "Batch preprocessing/automated pipeline for multi-volume CT", "Exportable quantitative metrics (CSV ~4,000 metrics)", "PDF and DICOM-format analysis reports", "Research-oriented outputs and validated quantification metrics" ], "optional_modules": [ "Fissure completeness analysis" ], "integrations": [ "PACS (DICOM workflow)", "Blackford Analysis (partner/marketplace)", "Sectra (marketplace/integration)", "Alma Medical marketplace", "Hospital RIS/EMR via standard imaging/report exchange" ], "data_standards": [ "DICOM", "HL7 v2", "CSV" ], "api_available": "unknown", "system_requirements": "DICOM-compatible CT input; Windows workstation/server; GPU recommended for AI; PACS connectivity and storage for DICOM", "compliance": [ "FDA (US)", "CE (EU)", "MFDS (Korea)", "PMDA (Japan)", "TFDA (Taiwan)", "TGA (Australia)", "HSA (Singapore)", "ANVISA (Brazil)", "Health Canada" ], "certifications": [ "FDA 510(k) clearance(s)", "CE marking", "MFDS approval", "PMDA approval", "TFDA approval", "TGA approval", "HSA approval", "ANVISA approval", "Health Canada approval" ], "security_features": [ "DICOM pseudonymization/anonymization support", "Role-based access control (RBAC)", "Audit logging", "Encryption for data storage and transfer" ], "privacy_features": [ "Pseudonymization/anonymization (separate pseudonymization server product)" ], "data_residency": "On-prem deployments; cloud/hosting region options vary by customer and contract", "customers": [ "Temple Lung Center", "Temple Health", "Temple University Hospital", "Boramae Hospital", "Coreline North America" ], "user_reviews": [], "ratings": [], "support_channels": [ "email", "phone", "web demo/request a demo", "webinar" ], "training_options": [ "documentation", "webinars", "live_online", "on-site (by request)" ], "release_year": "2018", "integration_partners": [ "Blackford Analysis", "Alma Medical Imaging", "Coreline Soft (AVIEW platform)" ], "id": "P2020", "slug": "aview-copd", "type": "product", "version": "1.0", "last_updated": "2025-09-07", "links_json": { "self": "https://www.healthaidb.com/software/aview-copd.json" } }